Dryer Dimensions (in inches)
Exhaust Options:
Electric: 4-way via rear, right, left and bottom. Maximum recommended exhaust duct length
is 45 feet of 4” rigid ducting with two 90° elbows and a 4” dampered wall cap.
Gas: When viewed from the front of the unit, exhaust 3-way via rear, left and bottom.
Maximum recommended exhaust duct length is 15 feet of 4” rigid ducting with two 90°
elbows and a 4” dampered wall cap.
Circuit Requirements:
An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a
time-delay fuse, is required.
Electric Dryer Rating:
208/240V, 5600W, 24A, 60Hz
208V, 4400W, 22A, 60Hz
A special 208 volt heater, part # WE11X0101 is avaialable to reduce drying time in
208 volt installations.
Gas Circuit Requirements: An individual branch circuit fused for 15- or 20-amp is required
for each dryer.
Gas Dryer Rating: 115V; 60Hz
Gas (BTU/Hr): 22000. Factory equipped for natural gas. tested for LP gas. A conversion Kit is
required for LP gas.
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible
when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed
with your dryer.