GE DVMRe 4eZT Recording Equipment User Manual


 
0150-0198H 51 DVMRe Triplex eZ
q Main Menu Communications RS485
Connect several units to a single keyboard, or vice-versa. Up to
32 units (any combination of multiplexers and keyboards) can be
networked together. Use this menu to specify the units unique network address.
Save changes and exit the menu: Press the Enter button.
Exit the menu without making changes: Press the Menu button.
q Main Menu Communications Ethernet Settings
An ethernet connection can be used to connect to the unit from a
PC for the viewing of live or recorded images. Use this menu to
configure the Ethernet communications settings. Select from the
following:
Ethernet: Select Enable or Disable.
Hostname: The default Hostname is the unit’s serial number
without the dashes. The user should modify only when GnuDIP
is selected in the Name Service field.
DHCP: Select Enable or Disable. Enables dynamic IP addressing.
When DHCP is enabled, the IP address, Subnet Mask, Gateway,
and Server fields are dynamically addressed.
Name Service: Select from Disable, WINS or GnuDIP. Enabling
WINS registers the hostname and IP address within the current
Network. This ensures that you can connect to the Triplex by
hostname within the network. See the Note below for information
on configuring Dynamic DDS with GnuDIP.
DDNS Update Interval: Select the Dynamic Domain Name Server
interval. Select from Disable or from 1 to 1440 minutes.
IP Address / Subnet Mask / Gateway: Consult with a qualified Network Administrator or an MIS
professional to configure these settings if DHCP is not enabled.
Primary Name Server / Backup Name Server: The IP addresses of the Primary and Backup Name
Servers. Not required if DHCP is enabled.
Print Server: Enter the Print Servers IP address to enable the Print Image operation (Function and
Zoom).
TCP MTU Size: Select from Standard, 1400, and 1200. The MTU describes the maximum possible TCP
packet size. Standard (1500) is optimal for most ethernet network environments.
HTTP Port : Select the HTTP Port. Select from Port 0 to 65535. Shortcuts are available for port 80
(Camera 1 button) and 8080 (camera 2 button). Consult with a qualified Network Administrator or an MIS
professional to configure these settings.
Network Address
01