Korg GT-120 Musical Instrument User Manual


 
Precautions
Location
Using the unit in the following locations can result in a malfunction.
• In direct sunlight
• Locations of extreme temperature or humidity
• Excessively dusty or dirty locations
• Locations of excessive vibration
Power supply
Please connect the designated AC adaptor to an AC outlet of the correct voltage. Do
not connect it to an AC outlet of voltage other than that for which your unit is in-
tended.
Interference with other electrical devices
This product contains a microcomputer. Radios and televisions placed nearby may
experience reception interference. Operate this unit at a suitable distance from ra-
dios and televisions.
Handling
To avoid breakage, do not apply excessive force to the switches or controls.
Care
If the exterior becomes dirty, wipe it with a clean, dry cloth. Do not use liquid clean-
ers such as benzene or thinner, or cleaning compounds or flammable polishes.
Keep this manual
After reading this manual, please keep it for later reference.
Keeping foreign matter out of your equipment
•Never set any container with liquid in it near this equipment. If liquid gets into
the equipment, it could cause a breakdown, fire, or electrical shock.
Be careful not to let metal objects get into the equipment. If something does slip
into the equipment, unplug the AC adaptor from the wall outlet. Then contact
your nearest Korg dealer or the store where the equipment was purchased.
CE mark for European Harmonized Standards
CE mark which is attached to our company’s products of AC mains operated
apparatus until December 31, 1996 means it conforms to EMC Directive (89/
336/EEC) and CE mark Directive (93/68/EEC). And, CE mark which is attached
after January 1, 1997 means it conforms to EMC Directive (89/336/EEC), CE
mark Directive (93/68/EEC) and Low Voltage Directive (73/23/EEC).
Also, CE mark which is attached to our company’s products of Battery operated
apparatus means it conforms to EMC Directive (89/336/EEC) and CE mark Di-
rective (93/68/EEC).
THE FCC REGULATION WARNING (for U.S.A.)
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guar-
antee that interference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Unauthorized changes or modification to this system can void the user’s au-
thority to operate this equipment.
Owner's Manual
Parts of the GT-120
[TUNING TYPE] dial
LCD display
Meter
[AUTO/MANUAL] switch
[SOUND] switch
[NOTE] switch
[FLAT] switch
Tuning guide
[CALIB] switch
INPUT jack
Built-in mic
OUTPUT jack
DC IN jack
(connect to AC adapter)
Power switch(STANDBY/ON/ )
Tuning procedure
The GT-120 has two tuning modes: Meter mode (auto/manual) in which
you tune while watching a meter, and Sound mode (manual) in which
you tune to an audible reference tone.
Meter mode
1. If you are using an instrument with a pickup (such as an electric gui-
tar) or a mic, connect the instrument or mic to the INPUT jack of the
GT-120.
(If you connect the GT-120's OUTPUT jack to your amp etc., the sound
will be output thru the tuner. During your performance however, you
may want to turn the GT-120 power switch STANDBY to avoid noise.)
If a plug is inserted into the INPUT jack or OUTPUT jack, the built-in mic
cannot be used. Both jacks are mono. They cannot be used with stereo plugs.
If you wish to tune your instrument using the built-in mic, do not con-
nect a plug to the INPUT jack or OUTPUT jack. In steps 5 and 6, place
your instrument as close as possible to the built-in mic.
2. Turn the power switch to the ON or position. (At the position,
the power will be on, and in addition the display will be illuminated.)
When the power is turned on, the previously-selected reference pitch
(default setting: A=440 Hz) will be selected, and the GT-120 will be in
Meter mode (Auto)
3. If you wish to change the reference pitch (calibration), press the
[CALIB] switch.
Each time you press it, the reference pitch will rise 1 Hz. If you con-
tinue holding it, the pitch will rise continuously. The available range is
438 Hz–445 Hz.
4. Rotate the [TUNING TYPE] dial to select the appropriate instrument
or set to CHROMATIC.
Move the appropriate instrument name to the mark.
Each setting allows the following tuning. ( ): Default values for MANUAL
CHROMATIC
: C, C
, D, E
, E, F, F
, G, G
, A, B
, B (A, sound output: A4)
GUITAR : 6E, 5A, 4D, 3G, 2B, 1E (6E)
OPEN D : 6D, 5A, 4D, 3F
, 2A, 1D (6D)
OPEN E : 6E, 5B, 4E, 3G
, 2B, 1E (6E)
OPEN G : 6D, 5G, 4D, 3G, 2B, 1D (6D)
OPEN A : 6E, 5A, 4E, 3A, 2C
, 1E (6E)
DADGAD : 6D, 5A, 4D, 3G, 2A, 1D (6D)
BASS : LB, 4E, 3A, 2D, 1G, HC (LB) LB: Low B, HC: High C
5. Specify the note name.
When using AUTO
Play a single note on your instrument, and the name of the nearest note
will appear in the LCD display. Tune your instrument so that the cor-
rect note name is shown in the LCD display.
When using MANUAL
Press the [NOTE] switch until the note you wish to tune (C–B) appears
in the LCD display.
Each time you press the [AUTO/MANUAL] switch, the setting will switch
between AUTO and MANUAL.
Thank you for purchasing
the Korg GT-120 guitar/
bass chromatic tuner. Be-
fore you use the GT-120,
please read this owner's
manual carefully, and use
the GT-120 as directed.
Keep this manual for fu-
ture reference.
J
E F G 1
6. Play a single note on your instrument, and tune it so that the needle
of the meter is at the 0 position (center) and both indicators of the
tuning guide are lit.
While tuning, do not allow extraneous sounds to enter the mic.
Tuning is correct when the needle indicates the 0 position
(center) and both tuning guide indicators are lit.
AUTO : Meter mode (Auto)
MANUAL : Meter mode (manual)
SOUND : Sound mode (manual)
Reference pitch
(calibration)
Octave
(displayed only
for CHROMATIC)
Remaining
battery power
Flat tuning
String number
(not displayed
for CHROMATIC)
Note name
(C, C
, D, E
, E, F,
F
, G, G
, A, B
, B)
Sound mode
1. Make the settings described in steps 1–4 of "Meter mode."
2. Press the [SOUND] switch to enter Sound mode (manual).
3. Press the [NOTE] switch until the note to which you wish to tune
appears in the LCD display.
4. Listen to the pitch sounded by the GT-120, and tune your instrument
accordingly.
To return to Meter mode, press the [AUTO/MANUAL] switch.
Flat tuning
When the [TUNING TYPE] dial is set to GUITAR or BASS, you can use
Meter mode or Sound mode to tune to a pitch that is lowered by 1–4
semitones (
) for the specified note.
1. As described in "Meter mode" or "Sound mode," make the note you
wish to flatten by 1–4 semitones appear in the LCD display.
Set the [TUNING TYPE] dial to either GUITAR or BASS. Flat tuning can
only be used for these selections.
2. Press the [FLAT] switch to select the number of semitones that you
wish to lower the selected note.
The LCD screen will indicate
(1–4 semitones).
3. Tune your instrument.
Replacing the batteries, and
the memory function
As the batteries begin to run down, accurate tuning will become more
difficult. Check the battery indicator in the LCD display, and replace the
batteries as soon as necessary.
The batteries are also used to preserve the memory when the power is
turned off, allowing the reference pitch, meter mode (manual), and the
note you selected for Sound mode to be remembered (Memory function).
When the batteries are removed or if they run down completely, the various
settings preserved by the memory function will be reset. (If an AC adapter
is connected to the GT-120 and plugged into an AC outlet, the settings will
not be reset.)
Even if you are using the GT-120 with an AC adapter, you should leave
the batteries installed.
2. Insert two AAA
batteries. Be careful to
observe the correct
polarity (+, -).
1. Press lightly and slide in the
direction of the arrow to open
the lid of the battery case.
3. Close the lid of the battery
case.
Adjustment screw
Adjusting the zero point of the meter needle
If the GT–120 is jarred while being transported etc., or due to normal ag-
ing after extended use, the VU style meter may drift away from the 0
position (center). Please re-adjust the VU style meter to the 0 position so
that tuning will be accurate.
1. While holding down the [AUTO/MANUAL] switch, turn the power
switch ON, and check whether the meter needle indicates the 0 posi-
tion.
2. If it does not indicate the 0 position, refer to the diagram in the above
section "Replacing the batteries, and the memory function," open the
battery cover, and use a small Philips (+) screwdriver (such as a
jeweler's screwdriver) to rotate the adjustment control so that the
needle indicates 0.
3. After making the adjustment (or if the meter needle indicated 0 in
step 1), press any one of the switches to return to normal operation,
and close the battery cover.
Specifications
Scale : 12 note equal temperament
Range : A0–C8
Reference tone : C2–C7 (5 octaves)
Tuning modes : Meter (auto/manual)
Sound (manual)
Flat tuning : 1–4 semitones (semitone steps)
Calibration range : A4=438–445 Hz (1 Hz steps)
Detection accuracy : +/-1 cent
Sound accuracy : +/-1.5 cents
Tuning guide range : Auto (chromatic)
-50 cents– -3 cents :
-3 cents– +3 cents :
,
+3 cents– +50 cents :
Manual
-500 cents– -3 cents :
-3 cents– +3 cents :
,
+3 cents– +500 cents :
Connectors : INPUT (1/4” mono), OUTPUT (1/4” mono),
DC IN (9V)
Power supply : AAA batteries x 2 (3V), or AC adapter ( )
Battery life : Approximately 100 hours (Alkaline batteries,
Meter mode, A4 continuous input)
Dimensions (WxDxH) : 74 x 120 x 36mm [2.91" x 4.71" x 1.42"]
Weight :193g [6.8 oz] : including the battery
Included items : AAA batteries x 2 for checking operation
Options : AC adapter ( )
(sold separately)
* Appearance and specifications are subject to change without notice.
Using the stand
By opening the stand located on the back, you can position the GT-120 at
a convenient angle.
The VU style meter may drift from the
0 position (center) when the OT–120
is tilted. If this occurs, perform the
procedure described in “Adjusting the
zero point of the VU style meter”
while the unit is tilted, so that the VU
style meter points to 0.
© 2005 KORG INC.