Neumann.Berlin Condenser Microphones Microphone User Manual


 
Neumann-Information
183 August 1983
Some informations on RF-interferences in the Studio
Neumann condenser microphones are protected through various
means very effectively against RF interferences so that they
may be used also in those cases where other microphones due
to heavy RF radiation do not perform satisfactorily. Some of
our past years experiences pertaining to this Problem have
been collected here for the purpose of helping to identify
this type of interference and to simplify its removal.
1. RF frequencies always enter through the microphone cable
and never through the capsule housing.
2. All microphone cable couplings must be arranged so that
the cable shield is connected to the connector Shell at
both ends of the cable. It is not sufficient to connect
theshield only through the relevant plug Pins. The
shield must be soldered to the connector Shell. In case
of heavy RF rad'iation it is not sufficient to only clamp
the shield by means of a screw. All connecting cables
supplied by Neumann comply with these requirements. Very
often when our customers prepare their own cables the be-
fore mentioned interference Problems appear, because the
prerequisites are not adhered to during cable assembly.
3. Microphone cables with a woven shield have a remarkably
lower degree of covering an area than such cables using
counterrotating double reusen shielding. For this reason
cables with reusen shielding are remarkably better pro-
tecting against RF interference. Neumann microphone
cables are using this counterrotating double reusen
shielding. Cables which are shielded only through conduc-
tive plastic material are not RF-proof.
4. Only demodulated high frequencies appear as interference.
Semiconducter circuits, especially the gates of the
fieldeffect transistors, may therefore not have any
capacitive coupling to RF frequency Signals.
5. If it is not sure whether the demodulation happens in the
microphone or in other equipment to which the microphone
is connected,
it is recommended to test this by means of
a 200 Ohms equivalent resistor built into a plug which is
connected instead of the microphone, or with a dynamic
microphone.
GN1
CHARLOTTENSTRASSE 3 . D-l000 BERLIN 61 . POSTFACH 610469 . TELEGRAMM: NEUMANNACUSTIC
TELEFON: (030) 25993-0 . TELEFAX: (030) 25993-106 . TELEX: 164595 NEUAK D
Printed in Germany