Peavey PVM 46 Microphone User Manual


 
Diaphragm type:
Diamond coated
Element type:
Dynamic
Magnet composition:
Neodymium iron boron
Pick up pattern:
Hypercardioid
Front-to-back rejection:
15 dB (typical)
Impedance:
400 ohms, balanced
Frequency response:
45 Hz to 16 kHz
Sensitivity (at 1 kHz open
circuit voltage):
-48 dBV/Pa (1 Pa = 94 dB SPL)
Maximum:
SPL 140 dB
Case (housing):
Die-cast zinc
Finish:
Black rubberized paint
Pop filter:
Dual, integral, open-cell foam
Phasing:
Positive (inward) pressure on
diaphragm produces positive
voltage at Pin #2
Weight:
9.92 oz. (281 g)
Features:
• Diamond-coated
diaphragm
• Neodymium magnetic
design
• Hypercardioid polar
response
• Smooth, accurate
frequency response
• Ultra-high sensitivity
Description
Thank you for choosing the
Peavey PVM 46 diamond-
coated microphone. The PVM
46 is dynamic hypercardioid
and incorporates a neodymium
magnet—which has more
than twice the sensitivity of
conventional microphones—
and our diamond-coated
diaphragm for flawless
transient and frequency
response. The hypercardioid
polar response is one of
the most popular patterns
in the industry for use with
acoustic instruments. The
slightly narrow on-axis polar
pickup affords the vocal user
less bleed-over from other
instruments or vocals. The
rear reflection of the PVM 46
is typically 15 dB less sensitive
than the on-axis response. This
helps reduce feedback from
stage monitors and background
noise.
SPECIFICATIONS PVM
46