Yamaha EX5 Electronic Keyboard User Manual


 
96
Voice Mode
L (Loop)
Sets the loop point for the FEG. As seen in the
FOLLOWING diagram, this function sets the
position to be returned to after reaching the Decay 2
(loop point). Selecting “off” turns the loop function
off.
Settings: off, Hl (Hold), Atck (Attack), D1 (Decay 1)
This parameter is not displayed in the ENVELOPE
screen.
Hold Time
Sets the Hold Time.
Settings: 0~127
Attack Time
Sets the Attack Time.
Settings: 0~127
Dcy 1/2 Time (Decay 1/2 Time)
Sets the Decay 1/2 Time.
Settings: 0~127
Rel1/Rel2 Time (Release 1/2 Time)
Sets the Release 1/2 Time.
Settings: 0~127
Hold Level
Sets the Hold Level.
Settings: -128~0~+127
Attack Level
Sets the Attack Level.
Settings: –128~0~+127
Dcy 1/2 Level (Decay 1/2 Level)
Sets the Decay 1/2 level.
Settings: –128~0~+127
Rel1/Rel2 Level (Release 1/2 Level)
Sets the Release 1/2 Level.
Settings: –128~0~+127
Hl
(Hl)
At
(At)
D1
D2
(D1)
Loop Point
Loop
Filter EG
Loop
When Set to “HI”
Setting the Filter Envelope Generator
There are six Time settings (the speed of changes)
and six Level settings (the amount of changes) that
shape how the timbre of the sound changes over
time, from when a key is hit, then released, and how
the sound decays.
Press [F8] to select the ENVELOPE screen. Each
value can be set with the Envelope graphical display.
The level of a played note can be set to continue at a
defined level for a fixed period of time by setting the
Attack Level and the Attack Time. Then the level
change over time can be controlled by setting Dcy
1/2/3 Time/Level. Finally, when the key is released,
the pitch change over time can be controlled by
setting the Rel 1/2 Time/Level.
Time Velocity and Loop can also be set in the All
Parameters screen.
The level here refers to the amount of offset value
relative to the current cutoff frequency.
[F5]: AMP (Amplitude)
The Amplitude parameters set the volume of each
element. There are three menus available.
[F6]: PARAM (Parameters)
[F7]: SCALE
[F8]: EG (Envelope Generator)
[F6]: PARAM (Parameters)
Determines the output level for each element. A
different value can be set for each element.
Level
Sets the output level of each element.
Settings: 0~127
0
Attack
Level
Hold Time
Hold Level
Attack
Time
Dcy1
Time
Dcy2
Time
Rel1
Time
Rel2
Time
Dcy1
Level
Dcy2
Level
Key off
Key on
Time
Cutoff
Frequency
Voice/E.qx 5/21/98 11:30 AM Page 96