PDS • User’s Guide 85
4. Operation
Using Front-Panel Lockout
rëáåÖ=cêçåíJm~åÉä=içÅâçìí
The PDS includes two front-panel lockout modes:
• Full lockout mode, which locks the front panel from all source selections
• Executive mode, which locks all front panel selections except the nine input
buttons (1 through 8 and SDI) and LOGO. In Executive mode, the user can
transition from one input source to another without pressing TAKE.
cìää=içÅâçìí=jçÇÉ
In the full lockout mode:
• All button pushes and all turns of the rotary knobs will be ignored.
• All Ethernet and serial communications commands will function normally.
• All button lights will continue to reflect the proper state of the inputs.
Use the following steps to fully lock and unlock the front panel:
1. Press and hold the SEL and ESC buttons simultaneously for 3 seconds. Once
this button combination has been detected, the following display appears:
Figure 4-69. System Message: Lockout Enabled
2. To disable the front panel full lockout mode, press and hold the SEL and ESC
buttons simultaneously for 3 seconds. When the button combination is detected,
the system returns to the menu that was displayed before full lockout mode was
enabled.
See also “Executive Mode” on page 71.
Front Panel
Lockout Enabled