A SERVICE OF

logo

130 PDS • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Setting Up For The Encore or ScreenPRO-II Controller
pÉííáåÖ=ré=cçê=qÜÉ=båÅçêÉ=çê=pÅêÉÉåmolJff=`çåíêçääÉê
The Barco Remote Control Submenu sets up the PDS for remote control
through a Barco Encore or ScreenPRO-II Controller.
Figure B-1. Remote Control Submenu (sample)
To connect a PDS to an Encore or ScreenPRO-II Controller, use the following
procedure:
1. On the Ethernet Submenu, enable DHCP mode and obtain an IP address for the
Encore Controller.
2. On the Ethernet Submenu, select Remote Control. The Barco Remote Control
Submenu appears, as shown in the preceding illustration.
3. The Unit ID defaults to 25. To change this setting, select Unit ID and scroll to
another number. Select an ID that is not being used by other devices.
4. In the IP field, scroll through the four fields to enter the IP address of the
appropriate controller. When you select IP, the last character in the first field
becomes available. Turn the ADJUST knob to change the value.
As you continue turning the knob, you can change all three values in this field.
Values range from 000 to 255 in all four fields.
5. Press SEL to accept your change in the first field. The last character in the next
field becomes available.
6. Continue until you have entered the IP address you want. Press SEL again.
7. In the Connect field, select ON. The following message appears:
Figure B-2. Remote Connection Message
REMOTE CONTROL
> Unit ID 25
IP 192.168.000.001
Status n/a
Connect OFF
Note
The default IP address of the Encore Controller is
192.168.0.1.
The default IP address of the ScreenPRO-II Controller is
192.168.0.2.
Attempting remote
connection
Please wait ....