AKG Acoustics C 480 B comb-ULS Microphone User Manual


 
17
The following values for Rv (or 2 x Rv) are stan-
dardised:
U = Rv 2 x Rv
48 V ± 4 V 3300 Ohm 6800 Ohm
The resistors 2 x Rv have to be of at least 0.5 %
tolerance type to satisfy the symmetry requirements.
In case where single ended (grounded) amplifier
inputs, or where no input transformers are available,
either capacitors or optional transformers have to be
wired into the audio lines to prevent any current
leakage into the input circuitry.