3. SPECIFICATIONS
AUDIO INPUTS
Mic 40 dB Gain, elec. balanced input
Phono 1, 2 and 3 40 dB Gain @ 1 kHz, unbalanced
inputs
Line 1, 2 and 3 0 dB Gain, unbalanced inputs
AUDIO OUTPUTS
Master max. +21 dBu @ +10 dB (Line In)
Booth max. +21 dBu @ +10 dB (Line In)
Tape type. 0 dBu Phones
type. 125 m @ 1% THD
EQUALIZER (+/-8 dB)
Stereo Low +12 dB/-32 dB @ 50 Hz
Stereo Mid +12 dB/-32 dB @ 1.2 kHz
Stereo High +12 dB/-32 dB @ 10 kHz
Mic Low +12 dB/-32 dB @ 50 Hz
Mic Mid +12 dB/-32 dB @ 1.2 kHz
Mic High +12 dB/-32 dB @ 10 kHz
TALKOVER BUTTON (MIC) -16 dB
LAMP (BNC) 12 V/400 mA
GENERAL
Signal-to-noise
ratio (S/N) > 87 dB (Line)
Crosstalk > 70 dB (Line)
Distortion (THD) < 0.05%
Frequency response 20 Hz - 20 kHz
Gain control range -16 dB - +6 dB
POWER SUPPLY
Mains Voltage USA/Canada 120 V ~, 60 Hz
U.K./Australia 240 V ~, 50 Hz
Europe 230 V ~, 50 Hz
General
Export Model 100 - 120 V ~, 200 - 240 V ~, 50 - 60 Hz
Power Consumption max. 15 W
Fuse 100 - 120 V ~: T 500 mA H
200 - 240 V ~: T 315 mA H
Mains Connection Standard IEC Receptacle
DIMENSIONS/WEIGHT
Dimensions
(H x W x D) approx. 2.4"/3.6" (61 mm/91 mm)
x 10" (254 mm)
x 12" (305 mm)
Weight approx. 2.4 kg
The BOOTH output gives you another possible way to
connect an amplifier. It is controlled by the BOOTH control
on the front panel. Through this output you can operate
monitor speakers or even provide another area with sound.
The MASTER output is for connecting an amplifier and is
adjusted using the MASTER control.
+ Always turn the power amps on last to avoid inrush
currents that can easily damage your speakers.
And, to avoid sudden and unpleasant surprises
for your ears, make sure there is no signal at the
DX626 before turning on the power amps. To be
sure, slide all the faders to the bottom and switch
all controls to zero.
This is the connector for the power cable. This is where
the advantage of the sophisticated internal power supply
can be seen: the pulse behaviour of each amplifying circuit
is mainly determined by the voltage reserves available.
Each mixing console is equipped with numerous
operational amplifiers (op amps) to process line level
signals. Due to limited output of their power supplies,
many mixing consoles show signs of stress when
subjected to heavy loads. But not your DJX400: the sound
is always clear and transparent.
FUSE HOLDER / VOLTAGE SETTING. Before connecting
the unit to the mains, ensure that the voltage setting
matches your local voltage. Blown fuses should only be
replaced by a fuse of the same type and rating. On some
units, the fuse holder can be switched to one of two
positions, i.e. 230 V and 115 V. N.B: should you desire to
operate the unit outside Europe at 115 V, a higher fuse
rating is required.
PRO MIXER DX626 SERIAL NUMBER. Please take the
time to complete and return the warranty card within 14
days of the date of purchase. Or, simply register online at
www.behringer.com.
3. SPECIFICATIONS
BEHRINGER makes every effort to ensure the highest standard of
quality. Necessary modifications are carried out without notice. Thus, the
specifications and design of the device may differ from the information
given in this manual.