Cisco Systems SMD48FXSE Drums User Manual


 
1-7
Cisco VG350 Voice Gateway Hardware Installation Guide
OL-25970-01
Chapter 1 Overview of the Cisco VG350 Voice Gateway
Physical Description and LEDs
Temperature
(short-term per NEBS/1800m
max altitude)
23 to 122°F (–5°C to 50°C)
Operating altitude maximum 13,123 ft (4000 m)
Note For China, the unit cannot operate above 2000 m. The internal AC power supplies
do not meet the new Chinese Safety requirements for products that operate in the
2001-5000 m range.
Transportation and Storage
Non-operating temperature –40 to 158°F (–40 to 70°C)
Non-operating humidity 5 to 95% RH
Non-operating altitude 15,000 ft (4570 m)
Acoustic
Acoustic: Sound Pressure
(Typical/Maximum)
57.6 to 77.6 dBA
Acoustic: Sound Power
(Typical/Maximum)
67.8 to 84.7 dBA
Compliance
Safety compliance
IEC 60950-1, Safety of information technology equipment
EN 60950-1, Safety of information technology equipment
UL 60950-1, Standard for safety for information technology
equipment [US]
CAN/CSA C22.2 No. 60950-1, Safety of information technology
equipment including electrical business equipment [Canada]
AS/NZS 60950.1 2003
IEC60950, 3rd edition [PRC]
IEC60950, 2nd Edition [Mexico]
Table 1-4 Cisco VG350 Voice Gateway Technical Specifications (continued)
Description Specification