PlayLink is automatically active after a software update, and the PlayLink icon
will only appear on the CAN-Bus confi guration screen of a Delta series disc
player.
PlayLink can only select a single input per disc player. It is therefore
not designed for users who regularly play both CDs and DVDs
through diff erent inputs from a single disc player. When PlayLink is
active the disc player will default to the same input every time play is
pressed, regardless of whether it is playing CD or DVD.
amp info Available for amplifi ers only, this screen displays the data provided by the
heatsink and AC Module temperature sensors.
NOTE:  is feature is only accessible when the target amplifi er is on.
event log Reserved for amplifi ers, this feature is a protection circuitry event log which can
only be accessed when the target amplifi er is in standby.  e protection circuit
shuts down the amplifi er or channel if it overheats or if its output could damage
your speakers.  e event log details the circumstances surrounding the amp
going into protection and should be referred to in situations that require the
intervention of your dealer or Classé customer support.
e log can report the following events interpreted as follows:
+ve slow blo trip & -ve slow blo trip —  e average current has
reached the safe operating limit.
+ve fast blo trip & -ve fast blo trip —  e peak current has
reached the safe operating limit.
over temperature trip —  e unit temperature has reached the
safe operating limit.
DC protection trip
e DC output level has reached the safe
operating limit.
Communication failure —  ere has been a loss of
communication between the amp’s system monitoring sensors.
AC line trip —  e power supply has reached the limits of the
amp’s safe operating range.
ese events are rare and generally occur due to issues that are external to the
amp.  ey should be interpreted positively.  e amp is doing what it’s designed