Korg SQ-10 Recording Equipment User Manual


 
3.9. Reset
15 Reset In: Use this INPUT jack when you want less than the maximum number of steps in a sequence. Just
patch the Trig Out jack of the last step in the sequence to the RESET IN jack. When the sequence reaches that
step, it will be reset and begin again at step 1.
3.10. Output Voltage Control
16 Range Switch ( +/-1V < > +/-5V ): When you want to control synthesizer functions with a smaller voltage
range, use the +/-1V position.
17 LED's: These light emitting diodes give visual confirmation of the channels and steps in a sequence.
18 Voltage Controlled Knobs: These knobs are used to adjust the output voltage at each step in the sequence.
Put the mode selector in one of the stopped sequence mode, and then as you press the Step button adjust the
knobs one at a time to get the desired effect from the synthesizer to which the sequencer is connected.
3.11. Analog Mixer
19 Analog Mixer: This lets you add DC voltages. For example, you could add channel A and Channel B so that
channel A is used for rough adjustment, and channel B is used for fine adjustment, so that you obtain a very
accurate output voltage setting. If you connect a number of sequencers in series, this lets you put them together
into a single output jack.
3.12. Power Switch
20 Power Switch: After you turn on the switch and the lamp goes on, wait ten minutes for the sequencer to
warm up, then set the controls. This will assure you of reliable results.