Neumann.Berlin KMS 104 Microphone User Manual


 
KMS 104/105
KMS 105
KMS 104
Technical Data
Acoustical operating principle .......................... Pressure gradient transducer
Directional pattern ...................................................................cardioid/supercardioid
Frequency range .................................................................................... 20 Hz...20 kHz
Sensitivity at 1 kHz into 1 kohm ............................................................ 4.5 mV/Pa
Rated impedance.................................................................................................. 50 ohms
Rated load impedance................................................................................. 1000 ohms
Signal-to-noise ratio, CCIR
1)
(rel. 94 dB SPL) ............................................. 66 dB
Signal-to-noise ratio, A-weighted
1)
(rel. 94 dB SPL)............................... 76 dB
Equivalent noise level, CCIR
1)
................................................................................ 28 dB
Equivalent noise level, A-weighted
1)
............................................................18 dB-A
Maximum SPL for THD 0.5%
2)
....................................................................... 150 dB
Maximum output voltage .....................................................................................12 dBu
Dynamic range of the mic. amplifier (A-weighted) ............................. 132 dB
Supply voltage (P48, IEC 1938) .............................................................48 V ± 4 V
Current consumption (P48, IEC 1938) .......................................................3.5 mA
Matching connector ................................................................................................... XLR3F
Weight.............................................................................................................. approx. 300 g
Diameter .......................................................................................................................... 48 mm
Length............................................................................................................................ 180 mm
Selection of Accessories
IC 3 mt, Microphone cable BS 48 i, Battery supply N 248, Power supply
measured in free-field conditions (IEC 60268-4)
1)
according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
2)
measured as equivalent el. input signal
WSS 100, Windscreen
AC 25, Adapter cable