Important: The Lithium Polymer rechargeable batteries that power the microphones are not user
serviceable. Please contact Revolabs (www.revolabs.com) or your AV service provider for
replacement instructions and to assure the proper disposal method is used. Warning: Never
dispose of batteries in a fire because they may explode.
Either a solid RED LED (charging) or solid GREEN LED (100% charged) will appear to confirm that
the microphone is inserted properly in the Charger Base. The microphones are not transmitting audio
to the HD Base Station while in the Charger Base. In normal use, batteries should fully charge in
about 2 hours, but will ―quick-charge‖ to 80% capacity in approximately 1 hour and 20 minutes. Fully
charged microphones left in the Charger Base remain solid GREEN.
Updating the Revolabs HD
TM
Firmware
Revolabs HD
TM
Systems are field upgradable for the firmware portion of the Base Station and
microphones. The firmware must be sent to the Base station using the Revolabs HD Single/Dual
firmware loader. The software can be downloaded at www.revolabs.com/downloads.
Updating the HD Single/Dual Channel Base Station and HD Microphones
1. Connect to the Base Station using the mini-USB cable.
2. Pair both mics to the Base Station and make sure they are out of the Charger Base.
3. Start the Revolabs HD Firmware Loader software
4. Choose the desired firmware version from the location it was saved during download.
5. Choose whether you would like to update the Base Station, Mics, or Both.
6. Select OK. The Revolabs HD Firmware Loader will notify you when complete.
The HD Microphone firmware updates wirelessly during the firmware process as long as the
microphones are out of the Charger Base, paired to the Base Station, and communicating with the