Sennheiser EM 3732 Command Musical Instrument User Manual


 
20
Using the receiver
Connecting the headphones/adjusting the volume
The EM 3731 single receiver features a headphone output 2. The two
receivers of the EM 3732 or EM 3732 Command twin receiver have a
common headphone output
2. This common headphone output 2 allows
you to either monitor the audio signal of one receiver or to simultaneously
monitor the audio signals of both receivers.
̈ Set the headphone volume control
3 to the lowest volume by turning
it to the left as far as possible.
̈ Connect headphones with a ¼”(6.3 mm) stereo jack plug to the
headphone output
2.
To monitor the audio signals of one of the two receivers of a twin receiver:
̈ Press the headphone button
0 of the receiver whose audio signals you
want to monitor.
To simultaneously monitor the audio signals of both receivers of a twin
receiver:
̈ Simultaneously press the headphone buttons
0 of both receivers.
The audio signals of the left receiver are output via the left headphone
channel, the audio signals of the right receiver are output via the right
headphone channel.
̈ Increase the volume gradually.
To switch the headphone output off:
̈ Press the headphone button
0 of the receiver whose headphone
output you want to switch off.
Deactivating the lock mode
When the receivers are remote controlled via a PC and the supplied
“Wireless Systems Manager” software, their buttons can be locked via the
“Wireless Systems Manager” software.
To deactivate the lock mode:
̈ Press the esc button
6 until the progress bar is complete and the
status display appears.
The lock mode is deactivated and the settings can be made manually.
CAUTION! Danger of hearing damage!
Listening at high volume levels for long periods can lead to
permanent hearing defects.
̈ Set the volume for the connected headphones to the
minimum before putting the headphones on.
True Diversity Receiver EM 3732
300
100
30
10
10
50
100
PEAK
μV
RF
% DEV
790.80
03.03
B
C
A B
esc
save
sync
300
100
30
10
10
50
100
PEAK
μV
RF
% DEV
M
H
z
790.800
03.03
BANK
CH
A B
COM
AF
Hold esc to unlock