Shure A15TG Microphone User Manual


 
SPECIFICATIONS
Output Frequency
700 Hz +20%, when terminated with 150 Ω
Output Level
-41.5 +4.5 dBV (8.4 mV typical) when terminated with 150 Ω
Total Harmonic Distortion
5% typical for any output termination greater than or equal to 150 Ω
Output Impedance
<15 Ω
Battery Type
1.5 V alkaline
Temperature Range
Operating:-12° C to 50° C (10° F to 130° F)
Storage:-29° C to 74° C (-20° F to 165°F)
Case
Steel with gray enamel finish
Dimensions
19 mm (3/4 in.) diameter; 141 mm (5 17/32 in.) long
Certification
Conforms to European Union directives, eligible to bear CE mark-
ing; meets European Union EMC Immunity Requirements (EN 50
082-1, 1992).