Shure A95U Microphone User Manual


 
2
2. Unsolder the YELLOW lead from pin 3 and insulate the bare wire at the end of
the lead with the insulator from the ORANGE lead.
3. Solder the ORANGE lead to pin 3.
4. Rotate the XLR plug three turns to twist the leads, then replace the XLR plug
in the case. Tighten the lock screw to secure the XLR plug in place (turning
clockwise).
SPECIFICATIONS
Frequency Response
Flat, 20 Hz to 20 kHz. Response at 20 Hz no more than 3 dB down from flat.
Impedance
Low impedance: 75 to 300 Ω (supplied) or 19 to 75 Ω
Medium impedance: High (41 kΩ with 150-Ω source
on 75-to-300 Ω winding.)
YELLOW
BLACK
3
2
1
SLEEVE
TIP
ORANGE
GREEN
RED
HIGH IMPEDANCELOW IMPEDANCE
IMPEDANCES
GREN/YLW 75–300
Ω
GREN/ORN 19–75
Ω
BLK/RED HIGH