Shure KSM141 Microphone User Manual


 
6
SPECIFICATIONS
*20 Hz to 20 kHz; THD < 1%. THD of the microphone preamplifier when applied input signal is
equivalent to the cartridge output at specified SPL.
**S/N ratio is difference between 94 dB SPL and equivalent SPL of self-noise A-weighted.
Cartridge Type Permanently Biased Condenser
Frequency Response 20-20,000 Hz (see Figures 3 and 5)
Directional Polar Pattern Cardioid/Omnidirectional (see Figures 4 and 6)
Output Impedance 150 Ω (actual)
Attenuation Switch 0 dB,15 dB, or 25 dB attenuation
Low Frequency Response Switch Flat; -6 db/octave below 115 Hz;
-18 dB/octave below 80 Hz
Phantom Power 48 Vdc± 4 Vdc (IEC-268-15/DIN 45 596),
positive pins 2 and 3
Current Drain 4.65 mA typical at 48 Vdc
Common Mode Rejection 50 dB, 20 Hz to 20 kHz
Polarity Positive pressure on diaphragm produces positive
voltage on output pin 2 relative to pin 3
Dimensions and Weight 20 mm (0.8 in.) diameter, 145 mm (5.75 in.) long;
156 grams (5.5 oz.) (see Figure 7)
Sensitivity (typical, at 1000 Hz;
(1 Pa = 94 dB SPL)
-37 dBV/Pa
Self-noise
(typical, equivalent SPL;
A-weighted, IEC 651)
14 dB
Maximum SPL at 1 kHz
5000 Ω load (Attenuator on)
2500 Ω load (Attenuator on)
1000 Ω load (Attenuator on)
145 (160, 170) dB
139 (154, 164) dB
134 (149, 159) dB
Output Clipping Level*
5000 Ω load
2500 Ω load
1000 Ω load
15 dBV
9 dBV
3 dBV
Dynamic Range
5000 Ω load
2500 Ω load
1000 Ω load
131 dB
125 dB
120 dB
Signal to Noise Ratio** 80 dB