Once placement has been determined, the microphones can be permanently installed. First, drill the
hole in the selected area to allow the bottom entry cable to be conveniently routed out of sight. Then
use the pressure sensitive adhesive to keep the microphone firmly in place.
Drilling the hole:
1. Determine the cutting area for the bottom exit cable and drill a 1/2" (12.7 mm) circular hole.
Remove all debris from the mounting surface.
2. Route the cable through the drilled hole.
3. Connect the integrated XLR cable to a mixer or P.A. system.
Pressure Sensitive Adhesive
Re-Routing Cable for Bottom Exit (If your
MX392 is not BE configured)
MX392BE
1. Remove the grille.
2. Disconnect wires from screw terminals.
3. Grasp rubber boot within 1/2" of housing, us-
ing gas pliers. Rotate boot and cable ccw to
remove connector from threaded "L" bracket.
4. Remove cable from microphone housing.
5. Insert cable through access hole in micro-
phone base.
6. Insert cable connector through hole and
thread it into "L" bracket.
7. If desired, rubber strain relief can be reat-
tached to cable end or removed from cable
before fastening it to bracket.
8. Re-connect wires to proper screw terminals
on circuit board.
9. Insert supplied round rubber plug into unused
side cable exit.
10. Reinstall grille and foam screen.
11. Insert cable through hole in mounting
surface. Secure microphone to mounting
surface.
1. Thoroughly clean the application area with the included alcohol wipe. Removing the dust will allow
the microphone to adhere well.
2. Remove the adhesive backing and gently set the microphone into position.
3. Once the microphone is in position, firmly apply pressure to the microphone.
Note: The pressure sensitive adhesive will be extremely difficult to move once pressure has been
applied.
MX392BE/C
MICROFLEX
Bottom view of MX392BE/C with adhesive pads
12.7 mm
(1/2 in.)