Shure PG42USB Microphone User Manual


 
1000 Hz
98765432 98765432
+20
+10
0
–10
–20
dB
20 50 100 1000 10000 20000
Hz
14
Frequency Response 20 to 20,000 Hz
Polar Pattern Cardioid
Max SPL
(20 Hz to 20 kHz, <1% THD)
PAD OFF: 120 dB SPL
PAD ON: 135 dB SPL
Max SPL corresponds to full-scale digital output at minimum analog
gain setting
Switch Attenuator: 15 dB
Power Requirements USB-powered, 500 mA
Digital Noise Floor
(20 Hz to 20 kHz, A-weighted)
Minimum MIC GAIN setting: −81 dB
Maximum MIC GAIN setting: −78 dB
Sampling Rate up to 48 kHz
Bit Depth 16 bit
Peak Signal Indicator
(Tri-color)
OFF: −30 dB FS
Green: −30 to −12 dB FS
Yellow: −12 to 0 dB FS
Red: >0 (digital converter clipped)
Adjustable Gain Range 31 dB
Headphone Output 3.5 mm (1/8 inch)
SPECIFICATIONS