Specifications
Type
Electret Condenser
Polar Pattern
Cardioid
Frequency Response
50 to 20,000 Hz
Output Impedance
at 1 kHz, open circuit voltage
120Ω,actual
Sensitivity
at 1 kHz, open circuit voltage
-38 dBV/Pa [1] (12.7 mV)
Maximum SPL
1 kHz at 1% THD, 1 kΩ load
138 dB SPL
Polarity
Positive pressure on diaphragm produces positive voltage on pin 2
with respect to pin 3
Connector
Three-pin professional audio (XLR), male
Weight
383 g (0.8 lbs)
Housing
Cast Zinc
Power Requirements
48 V DC phantom power (4 mA)
[1] 1 Pa=94 dB SPL
20
15
10
5
0
-30
-25
-20
-15
-10
-5
dB
Hz
20 100 1k 10k 20k
0,61 m (2 ft.) from sound source
Frequency Response
1,000 Hz
Polar Pattern
Certifications
This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking.
The CE Declaration of Conformity can be obtained from: www.shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: 49-7262-92 49 0
Fax: 49-7262-92 49 11 4
Email: info@shure.de