Yamaha M3000-40C Musical Instrument User Manual


 
About the Scene Memory function
35
responding program change message will be transmit-
ted. If this is set to “ ” (local), the corresponding
program change will be transmitted even when you
select a scene for which data has not been saved, thus
allowing you to select programs on an external device.
(control change transmission/reception)
....................................................... oFF/GrP/on
This specifies whether or not control change messages
will be transmitted and received via MIDI IN/OUT. If
this is set to “ ,” control change messages will not
be transmitted or received. If this is set to “ ,” con-
trol changes 1–104 received from an external device
will switch the corresponding channel on/off. (If mute
groups can be used, control changes 105–112 can also
be used to switch mute groups 1–8 on/off.) Also,
when the ON/EDIT switches of the M3000 are oper-
ated, the corresponding control change will be trans-
mitted. If this is set to “ ,” only control change
numbers (105–112) which correspond to mute groups
will be transmitted.
(program change reception omni on/off)
...............................................................on/oFF
This specifies whether or not the MIDI channel speci-
fied by the CH (MIDI channel) parameter will be
valid. When this setting is “ ,” program changes will
be received on all MIDI channels. When this setting is
,” program changes will be received only on the
MIDI channel specified by the CH (MIDI channel)
parameter.
(echo back) ........................................on/oFF
When this parameter is “ ,” messages received at the
MIDI IN connector will be retransmitted from the
MIDI OUT connector.
However if a bulk dump request is received, bulk
dump data will be output, and the bulk dump request
message itself will not be retransmitted (echoed).
(bulk out) .....................................ALL/1–128
This operation transmits all scene memories (ALL) or
a specified scene memory (1–128) as MIDI bulk
dump data from the MIDI OUT connector. Select
” or “ ” ~ “ ” and then press the STORE
switch to begin transmission. During transmission,
the display will indicate “ .”
(bulk dump request) .....................ALL/1–128
This operation transmits a request for a bulk dump
from the MIDI OUT connector. If the respective
MIDI IN/OUT connectors of two M3000 units are
connected, such a request will cause all scene memo-
ries (ALL) or the specified scene memory (1–128) of
the other M3000 to overwrite the scene memory (or
memories) of this M3000. After selecting “ ” or
” ~ “
,” press the STORE switch to transmit the
bulk dump request MIDI message.
Control change table
The following table shows the M3000 channel/bus to
which each control number is assigned. If the CC
(control change) item is turned ON in utility mode, a
control change message with a value of 127 received
from an external device will turn on the correspond-
ing channel/bus, and a control change message with a
value of 0 will turn it off. In the same way, operating
the ON/EDIT switches of the M3000 will transmit the
corresponding control change message from the
MIDI OUT connector.
Also, if mute groups can be used (refer to page 36),
control change numbers 105–112 can be used to
switch mute groups 1–8 on/off.
Control No. ON/EDIT Switch Control No. ON/EDIT Switch
0 30 CH INPUT 30
1 CH INPUT 1 31 CH INPUT 31
2 CH INPUT 2 32 CH INPUT 32
3 CH INPUT 3 33 CH INPUT 33
4 CH INPUT 4 34 CH INPUT 34
5 CH INPUT 5 35 CH INPUT 35
6 CH INPUT 6 36 CH INPUT 36
7 CH INPUT 7 37 CH INPUT 37
8 CH INPUT 8 38 CH INPUT 38
9 CH INPUT 9 39 CH INPUT 39
10 CH INPUT 10 40 CH INPUT 40
11 CH INPUT 11 41
12 CH INPUT 12 42
13 CH INPUT 13 43
14 CH INPUT 14 44
15 CH INPUT 15 45
16 CH INPUT 16 46
17 CH INPUT 17 47
18 CH INPUT 18 48
19 CH INPUT 19 49 ST INPUT 1
20 CH INPUT 20 50 ST INPUT 2
21 CH INPUT 21 51 ST INPUT 3
22 CH INPUT 22 52 ST INPUT 4
23 CH INPUT 23 53
24 CH INPUT 24 54
25 CH INPUT 25 55
26 CH INPUT 26 56
27 CH INPUT 27 57
28 CH INPUT 28 58
29 CH INPUT 29 59