M7CL Owner’s Manual
Using control changes to control parameters
204
6
Use the buttons of the CONTROL CHANGE
MODE field to select the control change
transmission/reception mode.
You can choose one of the following two modes for
control change transmission/reception.
● NRPN mode (when the NRPN button is on)
The M7CL’s various mix parameters will be trans-
mitted and received on a single MIDI channel as
NRPN messages. If you select this mode, the
assignments in the list will be ignored.
● TABLE mode (when the TABLE button is on)
The M7CL’s various mix parameters will be trans-
mitted and received on a single MIDI channel as
control change messages.
7
Use the buttons of the CONTROL CHANGE
field to turn transmission and reception on/
off, and make settings for echo output.
Each button has the following function.
● Tx button
Switches control change transmission on/off.
● Rx button
Switches control change reception on/off.
● ECHO button
Selects whether incoming control changes will be
echoed out from the MIDI transmit port.
8
To change the event assignment for each
control number, press the corresponding
event.
The MIDI CONTROL CHANGE popup window will
appear. In this window you can specify the event
assigned to each control number. The window contains
the following items.
1 MODE field
Select the type of event.
B PARAMETER 1/2 field
In conjunction with the MODE field, this specifies the
type of event.
9
In the order of the MODE field → PARAME-
TER 1 field → PARAMETER 2 field, specify
the type of event you want to assign.
Use the ↑/↓ buttons to select an item. Press the OK
button to confirm the change and close the MIDI
CONTROL CHANGE popup window.
10
Assign events to other control numbers in
the same way.
When you operate the parameters you assigned on the
M7CL, control change messages will be transmitted to
external devices. Similarly, if the corresponding con-
trol change messages are sent from an external device
on the appropriate channel, the parameters assigned to
those control numbers will change.
• The channel on which control changes are transmitted and
received is specified by the MIDI SETUP page PORT/CH field
(
→
p. 198).
HINT
1
2
• If NRPN mode is selected as the control change transmis-
sion/reception mode, the settings in this window are ignored.
NOTE
•For details on the events that can be assigned to control
changes, refer to the appendix (
→
p. 270).
HINT
•You can also press the desired event in the field to select it.
•You can press a field to highlight the item you want to select,
and then turn one of the multifunction encoders to select an
event.
HINT
•You can use the CLEAR ALL button to erase all assignments
to control numbers. The INITIALIZE ALL button will return all
control number assignments to their default state.
• Assignments to control numbers are maintained as settings
for the entire system, rather than for individual scenes.
HINT