40 CHAPTER 2: INSTALLING THE SWITCH 7750
■ Tools
■ Phillips screwdriver
■ Flat-head screwdriver
■ Antistatic wrist strap
■ Cables
■ Console cable
■ AUX cable
■ Power cord and chassis ground wire
■ Interface cables for the selected interface modules
■ Equipment
■ The switch
■ Ethernet 100BASE-T Hub or LAN switch
■ Channel service unit/data service unit (CSU/DSU) or other data
communications equipment (DCE) equipment (such as a modem)
■ Configuration terminal, such as a PC
■ Additional equipment for the selected interface modules
Installing the Chassis You can install the Switch 7750 in a standard, 19-inch cabinet or on a workbench.
Installing in a Standard
Cabinet
When you are ready to install the Switch 7750 in the cabinet:
1 Carry the switch to the front of the cabinet. At least two people are required to
move the switch.
2 Put the switch on the tray or the guides and push it into the cabinet.
3 Fix the switch in the cabinet with the combination screw and floating nuts that are
shipped with the switch.
Installing on a
Workbench
To install the switch on a workbench, take the following precautions:
■ Ensure that the workbench is smooth and stable.
■ Leave a heat-dissipation clearance in the front and back of the switch of more
than 1 m (3 ft) and at least 0.8 meters (2.5 ft) away from the walls on the sides.
■ Do not put heavy objects on the switch.
Installing the Cabling
Rack
To install the cabling rack:
1 Attach the rack brace to the left side of the chassis (opposite the fan frame).
2 Insert the wiring channel into the brace and fasten the screws.