60 CHAPTER 4: PROBLEM SOLVING
Switch. The monitoring system polls the fan status at periodic intervals
while the unit is powered up.
If one fan has failed in the Switch, a warning message will be generated
in the following ways:
■ RMON Email Notification — If configured, you will receive
notification of the fan failure via email, SMS (Short Message Service),
or pager.
■ RMON Trap — If configured, an RMON trap is generated and sent to
the management workstation.
For further information about RMON, refer to “Chapter 7: Status
Monitoring and Statistics” in the Switch Implementation Guide supplied
in PDF format on the CD-ROM that accompanies the Switch.
If more than one fan has failed in the Switch, a warning message will be
generated by RMON Email Notification, RMON Trap and also in the
following ways:
■ Command Line Interface — An indication of a general hardware
failure is provided through the Top level menu displayed when logging
on to the CLI. For more detailed information about the failure select
the system summary command.
■ Web interface — An indication of fan failure is provided through the
Device Summary table for the specific unit. In addition all Summary
tables turn red to indicate the fan failure.
If a fan failure warning message is generated:
1 Power off the unit.
2 Check that the air vents are not obstructed.
3 Power cycle the unit. To do this, remove and reconnect the AC mains
supply. If the unit has no AC main supply, remove and reconnect the DC
RPS supply.
4 If another fan failure warning message is generated via the Command
Line Interface or the Web interface, return the unit.