![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/2d/72d4021c-633c-478b-bfb2-3b772b0948c9/72d4021c-633c-478b-bfb2-3b772b0948c9-bg1f.png)
Chapter 4 Parameter Settings|DD Series
4-7
Paramete
Explanation Settings
Factory
Setting
VF
VFP
SVC
FOC
FOC
02.09
Multi-function Output
(Relay2)
1: AC drive in operation 17 ○ ○ ○ ○ ○
02.10
Multi-function Output
(MO1)
2: Zero speed frequency signal
(including STOP)
0 ○ ○ ○ ○ ○
02.11
Multi-function Output
(MO2)
3: AC drive ready
0 ○ ○ ○ ○ ○
02.12
Multi-function Output
(MO3) (Communication)
4: Low voltage warning(Lv) 0 ○ ○ ○ ○ ○
5: Fault indication ○ ○ ○ ○ ○
6: Overhead warning (Pr.06.09) ○ ○ ○ ○ ○
7: Detection of braking resistor action
level
○ ○ ○ ○ ○
8: Warning indication ○ ○ ○ ○ ○
9: Over voltage warning ○ ○ ○ ○ ○
10: OD command ○ ○ ○ ○ ○
11: CD command ○ ○ ○ ○ ○
12: Demo Indication ○ ○ ○ ○ ○
13: Demo complete ○ ○ ○ ○ ○
14: Emergency stop indication ○ ○ ○ ○ ○
15: Force stop indication ○ ○ ○ ○ ○
16: Door close complete (limit) signal
output
○ ○ ○ ○ ○
17: Door open complete (limit) signal
output
○ ○ ○ ○ ○
18: Door close error
○ ○ ○ ○ ○
19: Position Complete Signal ○ ○ ○ ○ ○
20: Position Detection 1(for door close
only)
○ ○ ○ ○ ○
21: Position Detection 2(for door close
only)
○ ○ ○ ○ ○
22: Position Detection 3(for door close
only))
○ ○ ○ ○ ○
23: Position Detection 1(for door open
only)
○ ○ ○ ○ ○
24: Position Detection 2(for door open
only)
○ ○ ○ ○ ○
25: Position Detection 3(for door open
only)
○ ○ ○ ○ ○
26: PG feedback error ○ ○ ○ ○ ○
27: output signal when unable to open
the door
○ ○ ○ ○ ○
28: over torque (OT1) ○ ○ ○ ○ ○
02.13
Multi-function Output
Direction
0~65535 0 ○ ○ ○ ○ ○
02.14
Position Detection Signal 1
0.0~100.0% 25.0 ○ ○ ○ ○ ○
02.15
Position Detection Signal 2
0.0~100.0% 12.5 ○ ○ ○ ○ ○
02.16
Position Detection Signal 3
0.0~100.0% 7.5 ○ ○ ○ ○ ○