Y1-03-0244B 30
APPENDIX G - TECHNICAL SPECIFICATIONS
greater than 5 watts (typical: 6.3 watts)
±2 parts per billion/100ms
1*
Beacons are shipped from ACR with a Serialized code but can be reprogrammed at a service
center to other coded formats including nationality of registration.
>25 mW PEP (typical 80mW)
Every 50 seconds (approximately) (U.S. Protocol)
Minimum Battery
Operating Life
+24 hours minimum @ -4°F to +131°F (-20°C to +55°C)
Battery Replacement
Interval
Battery replacement due no later than 6 years from date of
manufacture, 5 years from date of install, or after emergency use
*Batteries meet the UN Classification for Non-dangerous goods
Size of beacon less
Antenna
2.31 x 5.81 x 1.25 in (5.87 x 14.76 x 3.17 cm) (SARLink™ View)
2.31 x 5.81 x 1.45 in (5.87 x 14.76 x 3.68 cm) (AquaLink™ View)
High-impact and UV-resistant plastic
ACR-treuse™ (High-visibility yellow)
8.9 oz (252 g) without belt clip (SARLink™)
9.2 oz (260 g) without attachment clip (AquaLink™)
Bright White, I flash per 3 seconds
Factory tested to 16.4 ft (5 m) for 1 hour and to 32.8 ft (10 m) for 10
minutes, both at room temperature
See section 5 “Distinguishing PLB Features”, page 8
-4°F to +131°F (-20°C to +55°C)
-40°F to +158°F (-40°C to +70°C)
PLB-350C meets the requirements of Federal Communications Commission
(FCC) Part 95 Subpart K. For all other type approval information, please visit