A SERVICE OF

logo

EXP-06E Access Control System Installation Instruction
Satcom Systems (International) Co., Ltd.
15
Model : SFLA-030-2L
Switching Power Supply
DC1 +12V(2A)
DC2 -12V (1A)
AC-L
DC2
AC-N
COM
DC1
FG
Connected to EXP-06 Controller Board
12V A (+)
12V B (-)
12V Output for Electric Lock (2 amp.)
12V (+)
12V (-)
AC220V Input
JP3 JP7
C5
Parallel Printer
Battery
JP1
25 pin
9 pin
RS485
RS232
RABCDEFGH I KLM OPNJQ
11 71 8 7
JP2
DATA 1 / STROBE
DATA 0 / DATA
BEEPER
NOT USE/ CARD PRESENT
LED
GND
+VDC
READER
(IN)
READER
(OUT)
Door Release Button
Door Sensor
2
3
5
6
5
Door Lock Relay Output
Programmable Relay Output
Alarm Relay Output
IBM Compatible PC
KEY PAD
JP14
DATA 1 / STROBE
DATA 0 / DATA
BEEPER
NOT USE/ CARD PRESENT
LED
GND
+VDC
RAM
Program
Chip
EXP-06E Controller Board
CPU
I/O 2
I/O 1
JP15
JP8
JP18
JP12
COM
DC2
C1 C2 C3
C4
JP5
13
JP4
13
232 75176
JP4 & JP5 Enable RS485
JP4 & JP5 Enable RS232
5VDC Output for Reader Supply
12VDC Output for Reader Supply
Sort Using Battery for Data Memory
JP1
3 1
3 1
JP16
Door Lock Relay Output (NO)
Door Lock Relay Output (NC)
JP2
Programmable Relay Output (NO)
Programmable Relay Output (NC)
JP3
Alarm Relay Output (NO)
Alarm Relay Output (NC)
JP7
Sort Open
JP15 Watch Dog Active Deactive
JP8 Duress Alarm Disable Enable
JP18 - - - -
JP12 12VDC ON OFF
RS232 Communication
C4 9 PIN 25 PIN
G32
H23
I57
RS485 Communication
C4 RS485/RS232 Converter
E RS485 (-)
F RS485 (+)