A SERVICE OF

logo

REMOVE COVER TO LOCATE C
COMMISSIONING
LIGHTING THE
BURNER
-
(Erg
4)
CAUTION:
NO SMOKING OR
NAKED LIGHTS
Open
the burner outer door
to expose the
gas
control combination
valve.
CAUTION:
BEFORE LIGHTING
ENSURE THAT
THE GAS VALVE KNOB
2 lS SET
IN THE OFF POSITION.
(SEE
EIG.A)
AND
THE ELECTRICAL SUPPLY
TO THE AGA
IS SWITCHED
ON.
'1.
Turn off union
gas
cock 1. Test the
gas
installation from
the meter cock
fof soundness and
puqe
2. Turn on
gas
supply to cooker and open
gas
cock 1. 3. Turn
the
gas
valve
control knob 2 anti-clockwise
to the
position
(se;
Flg,B).
Press down and hold the
knob in the
position
while depressing
the
piezo
lighter
3
several
times
until the
pilot
has
lit. This can be observed through
the viewing
window 4.
4. \Ahen
the
pilot
has lit continue
to hold the
gas
valve control knob
for approximately
30 seconds lf it
goes
out'
wait 3 minutes and
repeat the
procedure
holding for a little
longer.
5.
l,/',/hen
the
pilot
flame established, rotate
the
gas
valve control
knob
2
anticlockwise
to its low fire
position (see
fig-Cj. \4hefe upon the
main bumerwill automatically
light. Leave
in the low fire
position
for at least 30
minutes.