Aiphone AX Series 13710 (28 13 00) - 4
Specifier Notes: List standards referenced in this section, complete with designations and titles. This
article does not require compliance with standards, but is merely a listing of those used.
A. ISO 9001:2000 – Quality Management Systems – Requirements.
B. TIA/EIA 568 – Commercial Building Telecommunications Cabling Standard.
1.4 SYSTEM DESCRIPTION
Specifier Notes: Edit the system description as required for the project. Consult Aiphone Corporation
for more information.
A. Components:
1. Door stations.
2. Master Stations: Connect a maximum of seven 16-call add-on selectors Model AX-16SW.
3. Central Exchange Units (CEU): Connect a maximum of 3 add-on exchange units Model
AX-320C.
4. Power supply.
5. Other External Connections:
Specifier Notes: Access control system and CCTV system may require custom software programs, not
provided by Aiphone Corporation.
a. Access control system.
b. CCTV system.
c. CO line adaptor.
d. Video output.
e. PC.
B. Capacities:
1. Door Stations: Maximum 120 stations with 1 CEU Model AX-248C and 3 add-on
exchange units Model AX-320C.
2. Master Stations:
a. Maximum 4 stations with CEU Model AX-084C.
b. Maximum 8 stations with CEU Model AX-248C.
3. Power Supply:
a. Model PS-2420UL: 24 V DC, 2 A.
b. For Audio: 1.
c. For Video: 2.
4. Number of Talk Paths: 2.
5. Number of Video Paths: 2.
6. All Call: 1, to master stations only.
7. Video Monitor: 2, same as talk paths and video paths.
8. Scan Monitor: 1.
C. Calling Master Station from Door Station and Communicating:
1. Priority Levels for Calls from Door Stations:
a. Normal.
b. Priority.