Chapter 4: Install the HDMCII VDSL2 LAN Extender Module
(Extended Temp)
LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 13
4. Install the HDMCII VDSL2 LAN Extender Module (Extended Temp)
Before installing an HDMCII VDSL2 LAN Extender Module (Extended Temp),
set the options using the DIP Switches (refer to the DIP Switch Settings
section for more information).
Install HDMCII VDSL2 LAN Extender Module (Extended Temp) in any Black
Box High-Density Media Converter System II chassis. Each module requires
one slot in the chassis; always use HDMCII VDSL2 LAN Extender Module
(Extended Temp) in pairs with the Host module at the CO and the Remote
module at the CPE.
To install a module, remove the blank brackets (if present) covering the slots
where you will install the module by removing the screws on the outside
edges of the bracket. Slide the module into the chassis, via the card guides,
until the module is seated securely in the connector. Secure the module to
the chassis by tightening the captive screw. Save any blanks removed
during installation for future use.
Remote CPE modules can be installed in a managed or unmanaged chassis.
Remote CPE modules can only be managed from the connected Host CO
HDMCII VDSL2 LAN Extender Module (Extended Temp) installed in a
managed chassis. The user should always set remote DIP Switches to
provide a base value under VDSL line fault conditions. In addition, some
features may not be software configurable on the remote unit. After setting
the DIP Switches, install the HDMCII VDSL2 LAN Extender Module
(Extended Temp). Once the VDSL line is established, the line can be
monitored and configured through the iView
2
management software available
for download at
ftp://ftp.blackbox.com/anonymous/lan/Managed%20Media%20Converters/L
MC5200a/.