![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/e1/ae1a730d-b3c5-4ce4-98aa-e0ee428eb8be/ae1a730d-b3c5-4ce4-98aa-e0ee428eb8be-bg2c.png)
1248
1
2
3
4
5
6
7
8
9
10
11
12
13
11
14
15
Figure 12.2: Conettix Network System Connection diagram – D9133TTL-E/DX4020 and Bosch Control
Panels
Callout ᅳ Description
Callout ᅳ Description
1 ᅳ Bosch Control Panels 9 ᅳ D6100IPv6
2 ᅳ Connection – control panel serial device
interface (SDI) bus to D9133TTL-E or DX4020
bus terminals
10 ᅳ Connection – Ethernet hub to
Network Ethernet Module
3 ᅳ D9133TTL-E or DX4020 Network Interface
Module
11 ᅳ Network Ethernet Module
4ᅳ Connection – D9133TTL-E or DX4020
Ethernet port to Ethernet hub
12 ᅳ Connection – Network Ethernet
Module to D6600 COM4 port
5 ᅳ Host PC running D6200 Programming
Administrative Software
13 ᅳ D6600
6 ᅳ Connection – Ethernet hub to Host PC
NIC
14 ᅳ Connection – second Network
Ethernet Module to D6600 COM 1 port
(optional)
44 en | Network Communications
Conettix Communications Receiver/
Gateway
2012.11 | 08 | 4998122704 Installation and Operation Guide Bosch Security Systems, Inc.