Page 36 P/N: F01U035325-01 Copyright © 2007 Bosch Security Systems, Inc. DS7400Xi (4+) Reference Guide
Step 2: Assigning a Zone Function to the Zone
In this step, a Zone function is assigned to the Zone.
10.3 Zone Programming: Program Addresses (0031-0278)
In Zone Programming, each zone is defined according to its input (single or multiple zone input, or a DS7465) and its Zone Function
(1-30) or Output Function (1-24). The DS7465’s relay is the only device that will follow the output functions; its input loop will follow a zone
function. All single and multiple zone inputs will follow a zone function. See section 6.3 for further details.
Data Digit
1
2
1
2
3
4
5
6
7
8
0031
0032
0033
0034
0035
0036
0037
0038
0039-0278
01
02
03
04
05
06
07
08
00
Zone Number Address
Zone
Function
Default
Hint:
Address = Zone Number + 30
Options
Disable azone
Enter a Zone Function Value
Zone
Functio
Value
00
01-30
he DS7465 occupies two zones. The odd numbered
one of the zone pair is the input zone. The even
umbered zone of the zone pair is the output relay.
he output follows an output function.