![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/58/d58645f7-e3c9-4258-8fd1-adc81b42caba/d58645f7-e3c9-4258-8fd1-adc81b42caba-bg9.png)
DX4010i | Installation Instructions | 6.0 Remote Programming Direct Connection
Bosch Security Systems, Inc. | 1/05 | 4998141106C 9
Table 4: SDI Bus Address DIP Switch Settings
SDI DIP Switch Settings
SDI DIP
Switches
S1 S2 S3 S4 S5 S6 S7 S8
Module
Address
1 2 4 8 16 32
(Mode)
64
(Option/SDI)
128
(Checksum +1)
80*
ON ON ON ON OFF OFF OFF OFF
81
OFF ON ON ON OFF OFF OFF OFF
82
ON OFF ON ON OFF OFF OFF OFF
83
OFF OFF ON ON OFF OFF OFF OFF
84
ON ON OFF ON OFF OFF OFF OFF
85
OFF ON OFF ON OFF OFF OFF OFF
86
ON OFF OFF ON OFF OFF OFF OFF
87
OFF OFF OFF ON OFF OFF OFF OFF
88**
ON ON ON OFF OFF OFF OFF OFF
89
OFF ON ON OFF OFF OFF OFF OFF
8A
ON OFF ON OFF OFF OFF OFF OFF
8B
OFF OFF ON OFF OFF OFF OFF OFF
8C
ON ON OFF OFF OFF OFF OFF OFF
8D
OFF ON OFF OFF OFF OFF OFF OFF
8E
ON OFF OFF OFF OFF OFF OFF OFF
8F
OFF OFF OFF OFF OFF OFF OFF OFF
Positions 5, 6, and 8 are not used for SDI bus.
* Used for BIS, PC 9000, and other third party applications.
** Used for RPS and alternate communication.
SDI bus control panels (v6.0 or higher): D9412G, D7412G, D7212G, D9124, D9112, D7412, and
D7212.