Bosch Security Systems | 2003-09 | 9922 141 50502en
Plena Message Manager | Installation and Operating Manual | en | 21
• Briefly press one of the pushbuttons (9), e.g. #11. The corresponding trigger indicator LED (8) will flash and the
(upper) trigger indicator LEDs 1 to 6 will indicate the stored zones for pushbutton #11. The message indicator
LEDs (7) will only indicate the messages related to pushbutton #11. Their place in the sequence is not indicated.
• Use the pushbuttons (9) to toggle the zones 1 to 6 ON and OFF, thus indicating the new zone selection.
• Press the monitor pushbutton (3) briefly to clear the present message sequence for the selected pushbutton (9).
Pressing the monitor pushbutton (3) once more causes the message indicator LED #1 to flash; subsequent press-
ing causes the message indicator LEDs #2, 3, 4, etc. to flash. If the monitor pushbutton is pressed for more than
3 s the message indicator LED that flashed is selected as the first message of a new sequence for the selected
pushbutton (9). In this way up to four messages can be selected in a random order to be part of that announce-
ment. After the fourth message no more messages will be accepted.
• Press the program mode pushbutton (4) once again for more than 3 s to enter the new configuration data and to
exit the program mode.
• Repeat the above procedure for any of the other pushbuttons (9).
• If during this manual editing process a trigger input is activated, the unit will quit the program mode and the
requested announcement will be started.
• If in the program mode no pushbutton is pressed for approx. 25 s, the unit will automatically resume its normal
working mode, without storing the new configuration data.