A SERVICE OF

logo

Dinion Day/Night Camera Configuration | en 21
Bosch Security Systems Installation and Operation manual F.01U.163.823 | v1.0 | 2010.01
Use the up or down keys to scroll through a menu.
Use the left or right keys to move through options or to set
parameters.
When in a menu, quickly double-press the menu/select key
to restore the selected item to its factory default.
To close all menus at once hold down the menu/select key
until the menu display disappears or continually select the
Exit item.
Some menus automatically close after about two minutes; other
menus have to be closed manually.
4.2 Camera control communication (Bilinx)
This camera is equipped with a coaxial communications
transceiver (also referred to as Bilinx). In combination with VP-
CFGSFT, the camera setting can be changed from any point
along the coaxial cable. All menus can be accessed remotely
giving full control of the camera. With this method of
communication it is also possible to disable the local keys on
the camera.To avoid loss of communication on an installed
camera, the COMM On/Off selection is not available while
using remote control. This function can only be accessed with
the camera buttons. Bilinx communications can only be
disabled using the buttons on the camera.
Disabled camera buttons
When the Bilinx communications link is active, the buttons on
the camera are disabled.
Figure 4.3 Navigation
Up key
Menu/Select key (center)
Right key
Down key
Left key