34 en | Alternative Control Protocols AutoDome 600 Series Analog PTZ Camera
F.01U.270.005 | 2.0 | 2012.06 User Manual Bosch Security Systems, Inc.
4.2.2 Pelco Keyboard Commands
Pelco control commands are composed of a sequence of two (2) keyboard inputs with the
following convention: 1) a Command Number and 2) a Function key input.
The AutoDome uses the PRESET command key to save and recall presets (pre-positions) 1
through 99.
4.2.3 Pelco Keyboard Commands
NOTICE!
To save a preset, enter the desired number and hold the PRESET key for approximately two
(2) seconds. To recall a preset, enter the desired preset number (or command) and
momentarily press and release the PRESET key.
Keyboard Command User Action Description
0-Pattern Press Initiates recording continuous playback based upon
current Recording setting (A or B) in the Setup
Menu.
Press and hold Initiates recording based upon current Recording
setting (A or B) in the Setup Menu. Press ACK to end
recording.
1-Pattern Press Initiate Recording A continuous playback.
Press and hold Initiate Recording A. Press ACK to end recording.
2-Pattern Press Initiate Recording B continuous playback.
Press and hold Initiate Recording B. Press ACK to end recording.
3-Pattern Press Initiate the AutoDome standard preset tour (Tour 1).
4-Pattern Press Initiate the AutoDome custom preset tour (Tour 2).
1 – Aux On / Aux Off Press Activates / deactivates alarm output 1.
2 – Aux On / Aux Off Press Activates / deactivates alarm output 2.
3 – Aux On / Aux Off Press Activates / deactivates alarm output 3.
4 – Aux On / Aux Off Press Activates / deactivates alarm relay.
91 – Aux On Press Activate Zone Scan (display zone titles).
92 – Aux On Press Deactivate Zone Scan (re-move zone titles)