Installation.
Note:The extractor hood is intended to
hang from a horizontal ceiling capable of
supporting the weight of the hood.
(approximately 40 kg)
Step 1
• Carefully unpack the extractor hood and
component parts.
• With the assistance of a qualified in-
staller, mount the top extension adaptor
to the ceiling above the cooking surface.
• Cut a hole in the ceiling (where applica-
ble) to accept a power supply cord with
a fitted plug and an outlet pipe
Step 2
• Fit and secure the square tubes into the
four recesses on the extractor hood, as
shown, using the M8 bolts supplied.
Step 3
• Slide the lower chimney duct onto the
extractor hood as shown.
• Slide the top chimney duct ( the one
with the louvers) into the lower chim-
ney duct.
Step 4
• Remove the grease filters and lift the
extractor hood assembly and slot it into
the top extension adaptor.
• Adjust to a suitable height.
(minimum 750mm above the cooking
surface).
• Tighten the clamping bolts to hold the
extractor in place.
• Connect the outlet pipe if required and
insert the fitted plug into the 15A
socket.
Step 5
• Slide the upper chimney duct into place
against the ceiling.
• Fasten from the side.
• Fasten the lower chimney duct to the
extractor hood from underneath the ex-
tractor as shown.
• Replace the grease filters.
3 X M8
BOLTS ON
EACH SIDE
CLAMPING
BOLTS
1
2
3
4
5
2 SELF TAPPING
SCREWS
4 SELF TAPPING SCREWS
CEILING