![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/33/9333d6c2-6c76-4eda-ad8d-7f34f3504f41/9333d6c2-6c76-4eda-ad8d-7f34f3504f41-bg7.png)
Function Range Accuracy % rdg. + digits Resolution Input Protection Comments
2, 20, 200mA ±(0.8% + 10 digits) 0.0001,0.001,0.01mA 0.2A,250V fuse DCA
(MV-130)
10A ±(2.0% + 10 digits) 0.001A not fused
20µA
±(3.0% + 7 digits)
0.01µA
200µA
±(1.8% + 3 digits)
0.1µA
2, 20mA ±(1.0% + 3 digits) 0.001, 0.01mA
200mA, 2A ±(1.8% + 3 digits) 0.1mA, 0.001A
2A,250V fuse
ACA
(MV-110)
10A ±(3.0% + 7 digits) 0.01A not fused
20, 200 mA ±(1.0% + 3 digits) 0.01,0.1mA 0.2A,250V fuse ACA
(MV-120)
20A ±(3.0% + 7 digits) 0.01A not fused
2, 20 200mA ±(1.0% + 10 digits) 0.0001,0.001,0.01mA 0.2A,250V fuse ACA 6
(MV-130)
10A ±(2.0% + 10 digits) 0.001A not fused
Frequency: 40 to 400Hz
Maximum input:
10A (MV-110, MV-130), 20A (MV-120)
Average responding
15 sec. max @ 20A
200Ω
±(0.8% + 3 digits)
0.1Ω
2, 20, 200kΩ, 2MΩ
±(0.8% + 1 digits)
1, 10, 100Ω,1kΩ
20MΩ
±(1.0% + 2 digits)
10kΩ
Resistance
(MV-110, MV-120)
200MΩ
± (5.0% rdg +10d) +10 dig
100kΩ
200Ω
±(0.2% + 5 digits)
0.01Ω
2, 20, 200kΩ, 2MΩ
±(0.2% + 1 digits)
0.1, 1, 10, 100Ω
Resistance
(MV-130)
20MΩ
±(0.5% + 5 digits)
1kΩ
250V
DC or ACrms
Open circuit voltage <0.7V
RH 200M
Ω range: <75%
RH other ranges: <90%
On the 200M
Ω range a 1.0MΩ offset exists.
Subtract 1.0MΩ from all readings.