❏ Placement of Unit.
❏ Specified clearance maintained to cabinet surfaces.
❏ Unit Level- front to back, side to side.
❏ All packaging material and tie straps removed.
ELECTRICAL:
❏ Receptacle with 15 ampere circuit protection is provided for service cord connection.
❏ Adequate ground connection.
GAS SUPPLY:
❏ Connection: 1/2” NPT flex line with a minimum 5/8” diameter.
❏ The pressure regulator which is connected to the manifold is set for 4.0” W.C. for Natural Gas or 10” W.C.
for LP.
❏ Manual gas shut-off valve installed in an accessible location.
❏ Unit tested and free of gas leaks.
OPERATION:
❏ All internal packing materials are removed, i.e. below grates, around knobs, etc.
❏ Bezels centered on burner knobs and knobs turn freely.
❏ Each burner lights satisfactorily, both individually and with other burners operating.
❏ Low flame operation verified.
❏ All burner caps, burner rings and burner bases correctly seated in position, level, and do not rock or slide.
❏ Burner grates correctly positioned, level, and do not rock.