A SERVICE OF

logo

Troubleshooting
Troubleshooting User Interface Startup
Chapter 12 591
Connection to a Remote System Refused on Windows
or Novell NetWare
The response of the telnet <hostname> 5555 command is Connection
refused.
Action If the Data Protector Inet service is not running on the remote
system, run the omnisv -start command to start it.
If Data Protector is not installed on the remote system, install Data
Protector on the remote system.
Connection to Windows 98 Clients Fails
Problems connecting to a Data Protector Windows 98 client system can
be identified when using the telnet <hostname> 5555 command or
when the following error message appears in the Data Protector message
log window: Cannot connect to inet for getting filesystem list
on <hostname>.
Action Run the <Data_Protector_home>\bin\omnii95 command to make
sure that the Data Protector Inet service is running on the Windows
98 client.
Run the <Data_Protector_home>\bin\omnii95 -kill command to
stop the Data Protector Inet service on a Windows 98 client.