![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/fc/8fc6cad7-dc32-406a-9282-ff49f0679f8d/8fc6cad7-dc32-406a-9282-ff49f0679f8d-bg7.png)
B-Series configuration steps
7Fabric Interoperability: Merging Fabrics Based on C-Series and B-Series Fibre Channel Switches Application Notes
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [97]
Å Select the domain ID in the range 97-127, if change is
required
BB credit: (1..27) [16]
R_A_TOV: (4000..120000) [10000]
Å Ensure this value is 10000, should be
same for all switches in the fabric
E_D_TOV: (1000..5000) [2000] Å Ensure this value is 2000, should be same for all
switches in the fabric
WAN_TOV: (1000..120000) [0]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
SYNC IO mode: (0..1) [0]
VC Encoded Address Mode: (0..1) [0]
Core Switch PID Format: (0..1) [1]
Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
Virtual Channel parameters (yes, y, no, n): [no]
Zoning Operation parameters (yes, y, no, n): [no]
RSCN Transmission Mode (yes, y, no, n): [no]
Arbitrated Loop parameters (yes, y, no, n): [no]
System services (yes, y, no, n): [no]
Portlog events enable (yes, y, no, n): [no]
No changes.
Switch:admin>