![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/2d/12d0a734-6c87-493a-94df-3d1b169a7ab4/12d0a734-6c87-493a-94df-3d1b169a7ab4-bg21.png)
Hardware options installation 33
• Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options
are:
• The embedded controller supports non-hot-plug SATA hard drives. Drive LEDs are not supported.
• Optional SATA controllers support hot-plug SATA hard drives and drive LEDs.
• Optional SAS controllers support hot-plug SAS or SATA hard drives and drive LEDs.
Removing a hard drive blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
Remove the component as indicated.
Removing a hard drive
IMPORTANT: Hot-plug capability and drive LED support are only available when a supported
optional controller is installed in the server.
To remove the component:
1. Back up all data on the hard drive.
2. Power down the server (on page 16).
CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.