Uninterruptible Power
Uninterruptible PowerUninterruptible Power
Uninterruptible Power
Supplies (UPS)
Supplies (UPS)Supplies (UPS)
Supplies (UPS)
HP will be reselling high-end (10 kW and above) three-phase UPS systems from our partners. We will test and qualify a
three-phase UPS for Superdome. The UPS is planned to be available Q1 FY01.
All third-party UPS resold by HP will be tested and qualified by HP to ensure interoperability with our systems
We plan to include
ups_mond
UPS communications capability in the third-party UPS(s), thus ensuring consistent
communications strategy with our PowerTrust UPS(s)
We will also establish a support strategy with our third party UPS partners to ensure the appropriate level of support
our customer have come to expect from HP.
For more information on the product and to manage the reference sales process. Please go to
http://hpcp.grenoble.hp.com/
for more information.
APC Uninterruptible
APC UninterruptibleAPC Uninterruptible
APC Uninterruptible
Power Supplies for
Power Supplies forPower Supplies for
Power Supplies for
Superdome
SuperdomeSuperdome
Superdome
The Superdome team has qualified the APC Silcon 3-phase 20-kW UPS for Superdome.
There are several configurations that can be utilized depending on the Superdome configuration your customer is
deploying. They range from a 64-way Superdome with dual-cord and dual-UPS with main tie main to a 32-way Superdome
with single-cord and single-UPS. In all configurations the APC Silcon SL20KFB2 has been tested and qualified by the
Superdome engineers to ensure interoperability.
HP UPS Solutions
HP UPS SolutionsHP UPS Solutions
HP UPS Solutions
Product Number/
Product Number/Product Number/
Product Number/
Description
DescriptionDescription
Description
Quantity/
Quantity/Quantity/
Quantity/
Configuration
ConfigurationConfiguration
Configuration
Watt
WattWatt
Watt
VA
VAVA
VA
Technology
TechnologyTechnology
Technology
Family
FamilyFamily
Family
Package
PackagePackage
Package
Output
OutputOutput
Output
SL20KFB2
APC Silcon
3-phase UPS
Quantity 2/
8- or 16-cell dual cord/dual
UPS with main tie main
Quantity 1/
32- or 64-way single-
cord/single-UPS
20 kW
20 kVA
Delta conversion
on-line double
conversion
APC Silcon
3-phase
Standalone rack
Configurable for
200: 208 or 220V
3-phase nominal
output voltage
QJB22830
Switch Gear
Quantity 1/
8- or 16-cell dual cord/dual
UPS with main-tie-main
Quantity 0/
32- or 64-way single-
cord/single-UPS
N/A N/A N/A
Customer Design
for Superdome
N/A N/A
WSTRUP5X8-SL10
Start-Up Service
Quantity 2/
8- or 16-cell dual cord/dual
UPS with main-tie-main
Quantity 1/
32- or 64-way single-
cord/single-UPS
N/A N/A N/A N/A N/A N/A
WONSITENBD-SL10
Next Business Day
On site Service
Quantity 2/
8- or 16-cell dual cord/dual
UPS with main-tie-main
Quantity 1/
8- or 16-cell single-
cord/single-UPS
N/A N/A N/A N/A N/A N/A
NOTE:
NOTE: NOTE:
NOTE:
The APC Silcon 3-phase UPS solutions for Superdome must be ordered directly from APC. Please contact Ron Seredian at
rseredia@apcc.com
.
Superdome Server Watt Ratings for UPS loading
Superdome Server Watt Ratings for UPS loadingSuperdome Server Watt Ratings for UPS loading
Superdome Server Watt Ratings for UPS loading
Class
ClassClass
Class
Models
ModelsModels
Models
Watt Rating for UPS loading
Watt Rating for UPS loadingWatt Rating for UPS loading
Watt Rating for UPS loading
UPSs Typically Used
UPSs Typically UsedUPSs Typically Used
UPSs Typically Used
Superdome
8-cell
19 kW
SL20KFB2; 20 kW/20 kVA
Superdome
16-cell
19 kW each cabinet; 38 kW total
SL20KFB2; 20 kW/20 kVA; Quantity 2
QuickSpecs
HP 9000 Superdome Servers
HP 9000 Superdome ServersHP 9000 Superdome Servers
HP 9000 Superdome Servers
(PA-8600, PA-8700 and PA-8800)
(PA-8600, PA-8700 and PA-8800)(PA-8600, PA-8700 and PA-8800)
(PA-8600, PA-8700 and PA-8800)
System Management Features
DA - 11721 North America — Version 13 — April 1, 2005
Page 24