Netcool/OMNIbus Probe for Nortel CNM Reference Guide20
NetcoolIRPManager:
Failed to retrieve
EntryPointIRP object
from security
interface:
The probe has failed to take the
Corba Object of the Security IRP
and narrow it to its specific
type.
Check the value for the
SecurityIrpFtpCommand
property; change this value if
necessary.
Problem while trying
to connect to the IRP
points
The probe found a problem
while connecting to the
AlarmIRP or
NotificationIRP points.
Check the values set for the
AlarmIrpName, and
NotificationIrpName
property; change the values if
necessary.
Failed to ping
notification service
The probe found a problem
while connecting to the
NotificationIRP point.
Check the values set for the
NotificationIrpName
property; change the values if
necessary.
OperationNotSupported
Exception
The Nortel system doesn’t
support the Notification
IrpSystem.idl.
Contact the IBM support.
Communication failure
- lost connection to
NoticiationIRP:
CORBA.TRANSIENT
exception raised.
NotificationIRP is
down!
CORBA.OBJECT_NOT_
EXIST exception
raised.
NotificationIRP is
down!
Failed to Connect
Either, the server is
not running, the IOR
is out of date, or
probe cannot reach
remote Server
Cannot proceed.
Shutting down!
The NotificationIRP point
from the Nortel System is not
responding.
Check that the Nortel CNM
system is still running.
Failed to iterate
through resynch
alarms
There was a problem with the
resynchronization process.
Check that the Nortel CNM
system is running correctly.
Check that you have specified the
Resynch property correctly.
Table 7. Error messages (4 of 4)
Error Description Action