A SERVICE OF

logo

Symptom / Error FRU / Action in Sequence
186 System Board
190
(A depleted battery pack
was installed when the
power was on.)
Go to “Battery Checkout”
on page 30.
191XX
(PM initialization error.)
System board
192
(Fan error)
1. Fan
2. System board
195
(The configuration read from
the hibernation data storage
area does not match the
actual configuration.)
Check if the configuration
was changed.
For example, check if the
DIMM is added.
196
(A read error occurred in the
hibernation area of the hard
disk drive.)
1. Run the hard disk
drive test.
2. Hard disk drive
199XX
(Resume error.)
System board
1XX System board
225
(Unsupported memory
module)
1. Check if a supported
DIMM is installed.
2. DIMM Card
3. System board
2XX
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
1. Go to “Memory
Checkout” on
page 28.
2. DIMM
3. System board
301, 303, 304, 305, 3XX
(301: Keyboard error.)
1. Go to “Keyboard or
Auxiliary Input
Device Checkout” on
page 27.
2. Keyboard
3. External numeric
keypad
4. External keyboard
5. Keyboard/mouse cable
6. DC/DC card
7. System board
40 IBM ThinkPad 380XD, 385XD