INSTALLATION / HANDLING
25
enhttp://air.ingersollrand.com
60/50Hz IRN 30HP/ 22 kW IRN 40HP / 30 kW
TAS
non−TA S
TAS
non−TA S
COMPRESSOR
Nominal pressure
PSIG (bar)
150
(10.34)
150
(10.34)
Flow rate @ 150 PSIG (10.3 bar)
ACFM (m
3
/MIN)
1,
4
109
(3.09)
112
(3.17)
142
(4.02)
146
(4.14)
Flow rate @ 125 PSIG (8.6 bar)
ACFM (m
3
/MIN)
2,
4
120
(3.40)
125
(3.54)
152
(4.31)
158
(4.48)
Flow rate
@ 115 PSIG (8 bar) ACFM (m
3
/MIN)
3,
4
125
(3.54)
130
(3.68)
158
(4.48)
164
(4.65)
Airend discharge temperature. 228_F (109_C) Trip point
Ambient operating temperature
(min.) → (max.)
35_F (+2_C) → 104_F (+40_C)
MOTOR
Nominal power 30HP / 22kW 40HP / 30kW
Insulation class F
COOLING SYSTEM − Air cooled
Cooling air flow 2700ft
3
/min (76.5m
3
/min)
Maximum ∆P in air ducts 0.25 inWg (6.4mmH
2
O)
Compressed air outlet ∆T N/A 15_F (8.3_C) N/A 20_F (11_C)
GENERAL DATA
Separation volume 2.8 gallons (10.7 Litres )
Coolant capacity 5.5 gallons (21 Litres )
Weight − base mount unit 1350 lbs (612 kg)
Weight − 120 gallon Receiver mounted 1720 lbs (780 kg)
Weight − 240 gallon Receiver mounted 1891 lbs (858 kg)
Weight − 500 Litre Receiver mounted 1772 lbs (804 kg)
Weight − 750 Litre Receiver mounted 1891 lbs (858 kg)
DRYER ENGINEERING DATA 50 / 60Hz
Electrical protection class (std) NEMA 1
(IP 20)
Factory refrigerant charge (oz/g) 45 oz
1.27 kg
Refigeration type 134 A
1 Assuming a 6 psi (0.4 bar) pressure drop through the TAS module.
2 Assuming a 9 psi (0.62 bar) pressure drop through the TAS module.
3 Assuming a 10 psi (0.69 bar) pressure drop through the TAS module.
4 Flow rate will decrease as DP through the TAS module increases.