LED Indicator Messages
Projector Status POWER TEMP LAMP
Standby (Eco mode) Blue solid Off Off
Standby (Active mode) Blue flashing Off Off
Normal running mode
Flashing 30
seconds after
powering on and
then become
solid blue
Off Off
Normal cooling Blue solid Blue solid Red solid
Lamp ignition failed Blue solid Off Red flashing
Lamp life end Blue solid Off Red solid
Temp error Blue solid Blue flashing Off
Fan error Blue solid Blue solid Off
Color wheel or DMD
error
Blue flashing Blue flashing Red flashing
Quick resume
Blue flashing
(0.25 sec off then
0.25 sec on for
100 sec.)
Off Off
Eco
+
Blue flashing Blue flashing Off