A SERVICE OF

logo

9
Specifications
Continuous Power Output 60 watts/channel (20-20 kHz, < 0.03%, 8 ohms)
Total Harmonic Distortion (20Hz-20kHz) < 0.03% at rated power, 1/2 power, or 1 watt
Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.03% at rated power, 1/2 power or 1 watt
Frequency Response
Phono Input 20Hz-15kHz, ±0.2dB
Line Level Inputs 10Hz-100kHz, +1, –3dB
Damping Factor (20-20,000 Hz, 8 ohms) 150
Line Input Sensitivity / Impedance 160 mV / 24 kOhms
Line Input Overload 5 V
Phono (MM) Sensitivity / Impedance 2.4mV /47 kohms
Input (Phono) Overload 170 mV
Preamplifier Output / Impedance 1V / 470 ohms
Signal to Noise Ratio (IHF “A” weighted) >95 dB
Power Requirements
USA: 115 Volts, 60 Hz
EC: 230 Volts, 50 Hz
Power Consumption 300 Watts
Dimensions (W x H x D) 430 x 92 x 355 mm
17 x 5
5
/8 x 14 inches
Front Panel Height 80mm / 3
3
/16 inches
Weight (net) 7.8 kg, 17.2 lbs.
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.
Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co, Ltd., Tokyo, Japan.
Troubleshooting
Most difficulties in audio systems are the result
of incorrect connections, or improper control
settings. If you encounter problems, isolate the
area of the difficulty, check the control settings,
determine the cause of the fault and make the
necessary changes. If you are unable to get
sound from the RA-1062 refer to the sugges
-
tions for the following conditions:
Power Indicator Is Not Lit
The power indicator should be lit whenever the
RA-1062 is plugged into the wall power outlet
and the POWER switch is pushed in. If it does
not light, test the power outlet with another
electrical device, such as a lamp. Be sure the
power outlet being used is not controlled by
a switch that has been turned off.
Fuse Replacement
If another electrical device works when plugged
into the power outlet, but the power indicator
still will not light when the RA-1062 is plugged
into the wall outlet, it indicates that the internal
power fuse may have blown. If you believe this
has happened, contact your authorized Rotel
dealer to get the fuse replaced.
No Sound
Check the signal source to see if it is func-
tioning properly. Make sure the cables from
the signal source to the RA-1062 inputs are
connected properly. Be sure the LISTENING
selector is set to the proper input. Be sure the
SPEAKERS selector is set to the proper posi
-
tion. Check the wiring between the RA-1062
and the speakers.
English